This 55-year-ancient female were built with a chest X-ray throughout a follow-up visit for that control over her cancer of the breast. The chest area X-ray shown an embolized venous catheter superimposed upon the mediastinum. It had been determined the catheter from the patient&s arm port had broke and embolized towards the lung circulation. The catheter was retrieved, within the interventional radiology suite, under fluoroscopic guidance. The individual experienced no harmful effects. Subsequently, eventually later, the traditional vein port was removed along with a fresh arm port and connected catheter were inserted to facilitate the delivery from the patient'ngoing chemotherapy. (Source: Clinical and Developmental Immunology)